Evaluation of the apparent diffusion coefficient in patients with recurrent glioblastoma under treatment with bevacizumab with radiographic pseudores…

2017

Abstract Background Response Assessment in Neuro-Oncology Criteria (RANO), are used to asses response to first-line treatment of glioblastoma (GBM). Differentiation between response and pseudoresponse under treatment with Bevacizumab (BVZ) remains challenging. This study evaluates ADC changes in patients with radiographic pseudoresponse under treatment with (BVZ). Methods Patients (n = 40) with recurrent GBM under-treatment with BVZ underwent MRI before, two and four months after treatment with BVZ. In patients with radiological pseudoresponse (n = 11), ADC analyses were performed. Areas with decreasing T1 contrast enhancement (CE) and FLAIR signal decrease were manually selected and compar…

AdultMaleBevacizumabRadiographyPseudoresponseFluid-attenuated inversion recovery030218 nuclear medicine & medical imaging03 medical and health sciencesAntineoplastic Agents Immunological0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingIn patientAgedRadiological and Ultrasound TechnologyBrain Neoplasmsbusiness.industryMiddle Agedmedicine.diseaseHyperintensityBevacizumabbody regionsDiffusion Magnetic Resonance ImagingTreatment OutcomeFemaleNeurology (clinical)Neoplasm Recurrence LocalGlioblastomabusinessNuclear medicine030217 neurology & neurosurgerymedicine.drugGlioblastomaJournal of Neuroradiology
researchProduct

Controlling diffusion of 3He by buffer gases: a structural contrast agent in lung MRI.

2006

Purpose: To study the influence of admixing inert buffer gases to laser-polarized 3 He in terms of resulting diffusion coefficients and the consequences for image contrast and resolution. Materials and Methods: The diffusion coefficient of 3 He was altered by admixing buffer gases of various molecular weights ( 4 He, N2, and SF6). The influence of the pulse sequence and the diffusion coefficient on the appearance of MRI of (laserpolarized) gases was analyzed by comparison of basic theoretical concepts with demonstrative experiments. Results: Excellent agreement between theoretical description and observed signal in simple gradient echoes was observed. A maximum signal gain can be predicted …

InertMaterials sciencePhantoms ImagingDiffusionPhysics::Medical PhysicsBuffer gasResolution (electron density)Contrast MediaReproducibility of ResultsPulse sequenceImage EnhancementSignalMolecular physicsHeliumSensitivity and SpecificityDiffusion Magnetic Resonance ImagingIsotopesRestricted DiffusionEffective diffusion coefficientHumansRadiology Nuclear Medicine and imagingGasesLungJournal of magnetic resonance imaging : JMRI
researchProduct

Diffusion in Flashing Periodic Potentials

2005

The one-dimensional overdamped Brownian motion in a symmetric periodic potential modulated by external time-reversible noise is analyzed. The calculation of the effective diffusion coefficient is reduced to the mean first passage time problem. We derive general equations to calculate the effective diffusion coefficient of Brownian particles moving in arbitrary supersymmetric potential modulated: (i) by external white Gaussian noise and (ii) by Markovian dichotomous noise. For both cases the exact expressions for the effective diffusion coefficient are derived. We obtain acceleration of diffusion in comparison with the free diffusion case for fast fluctuating potentials with arbitrary profil…

PhysicsFluctuating Rectangular Periodic PotentialStatistical Mechanics (cond-mat.stat-mech)Mathematical analysisFOS: Physical sciencesSawtooth waveCondensed Matter - Soft Condensed MatterCondensed Matter PhysicsNoise (electronics)Electronic Optical and Magnetic Materialssymbols.namesakeAccelerationAdditive white Gaussian noisesymbolsSoft Condensed Matter (cond-mat.soft)Effective diffusion coefficientDiffusion (business)First-hitting-time modelBrownian motionCondensed Matter - Statistical Mechanics
researchProduct

Optimization of impurity profile for p-n junction in heterostructures

2005

We analyze the dopant diffusion in p-n-junction in heterostructure, by solving the diffusion equation with space-varying diffusion coefficient. For a step-wise spatial distribution we find the optimum annealing time to decrease the p-n-junction thickness and to increase the homogeneity of impurity concentration in p or n regions.

Diffusion equationMaterials scienceDopantCondensed matter physicsEpitaxial layerAnnealing (metallurgy)radiation defectsHeterojunctionCondensed Matter::Mesoscopic Systems and Quantum Hall EffectCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsCondensed Matter::Materials ScienceImpurityCondensed Matter::SuperconductivityHomogeneity (physics)Effective diffusion coefficientHeterojunctionp–n junctionOptimization of impurity
researchProduct

Small solid renal masses: Characterization by diffusion-weighted MRI at 3 T

2013

AIM: To describe the appearance of small solid renal lesions (≤3 cm) on diffusion-weighted magnetic resonance imaging (MRI) and to determine whether ADC measurements may help to differentiate benign from malignant small solid renal masses. METHODS AND MATERIALS: Thirty-five patients with 47 small renal masses (23 malignant, 24 benign) who underwent 3 T MRI of the kidney using diffusion-weighted sequences (b values of 0 and 1000 s/mm(2)) were retrospectively evaluated. Qualitative and quantitative analysis of diffusion-weighted images was performed. RESULTS: Most lesions were hyperintense to kidney on high b-value diffusion-weighted images and hypointense on apparent diffusion coefficient (A…

KidneyPathologymedicine.medical_specialtyAngiomyolipomamedicine.diagnostic_testbusiness.industryMagnetic resonance imagingGeneral MedicineHigh B-Valuemedicine.diseasediffusion-weighted MRImedicine.anatomical_structureADCmedicineEffective diffusion coefficientRadiology Nuclear Medicine and imagingNuclear medicinebusinessDiffusion MRIsmall solid renal lesion
researchProduct

Brain changes in long-term zen meditators using proton magnetic resonance spectroscopy and diffusion tensor imaging: a controlled study.

2013

Introduction: This work aimed to determine whether 1 H magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) are correlated with years of meditation and psychological variables in long-term Zen meditators compared to healthy non-meditator controls. Materials and Methods: Design. Controlled, cross-sectional study. Sample. Meditators were recruited from a Zen Buddhist monastery. The control group was recruited from hospital staff. Meditators were administered questionnaires on anxiety, depression, cognitive impairment and mindfulness. 1 H-MRS (1.5 T) of the brain was carried out by exploring four areas: bot…

MaleAnatomy and PhysiologyMagnetic Resonance SpectroscopyBiochemistryBrain mappingDiagnostic RadiologyBehavioral NeuroscienceNuclear magnetic resonancelong-term Zen meditatorsMultidisciplinarymedicine.diagnostic_testQRBrainNeurochemistryMiddle AgedMagnetic Resonance ImagingMental HealthDiffusion Tensor ImagingMeditationmedicine.anatomical_structureMedicineFemaleNeurochemicalsGlutamateRadiologyResearch ArticleAdultbrainScienceSuperior parietal lobuleNeurological SystemWhite matterFractional anisotropymedicineHumansEffective diffusion coefficientBiologybusiness.industryFunctional NeuroimagingMagnetic resonance imagingNeuroanatomyCross-Sectional StudiesPsicologianervous systemCase-Control StudiesPosterior cingulateFisiologia humanabusinessmeditatorNeuroscienceDiffusion MRIPLoS ONE
researchProduct

Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Functio…

2004

Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…

Malemedicine.medical_specialtyHigh-resolution computed tomographyHeliumPulmonary function testingIsotopesmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingFunctional evaluationmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingGeneral MedicineMiddle Agedrespiratory systemSingle Lung TransplantationMagnetic Resonance ImagingRespiratory Function Testsrespiratory tract diseasesLung densityPulmonary EmphysemaConcomitantFemaleRadiologyTomography X-Ray ComputedbusinessNuclear medicineLung TransplantationInvestigative Radiology
researchProduct

Diffusion Process in Quasi-One-Dimensional Structures as Elements of Novel Nanodevices

2012

The effective diffusion coefficient in two-phase one-dimensional model with the periodical distribution of inclusions in the effective medium approximation is calculated and generalization about a quasi-one-dimensional case is formed.

PhysicsDiffusion processDistribution (number theory)GeneralizationEffective diffusion coefficientQuasi one dimensionalStatistical physics
researchProduct

Hyperpolarized helium-3 gas magnetic resonance imaging of the lung.

2003

3He magnetic resonance imaging (MRI) is capable of producing new and regional information on normal and abnormal lung ventilation. The basis of 3He MRI involves "optical pumping" to hyperpolarize the 3He nuclei by photon angular momentum transfer. The hyperpolarized gas is administered via inhalation. 3He is an inert, nontoxic noble gas and absorbed in less than 0.1%. Imaging consists of a four-step protocol. 1) Gas density 3He MRI with high spatial resolution displays the distribution of a 3He bolus in a 10-second breath-hold. An almost homogeneous distribution is regarded as normal. Patients with lung diseases show multiple ventilation defects. 3He MRI has been shown to be more sensitive …

Materials sciencemedicine.diagnostic_testMagnetic resonance microscopyDynamic imagingPartial PressureMagnetic resonance imagingHyperpolarized Helium 3Air trappingHeliumMagnetic Resonance ImagingSensitivity and SpecificityPulmonary function testingNuclear magnetic resonanceIsotopesmedicineEffective diffusion coefficientHumansRadiology Nuclear Medicine and imagingmedicine.symptomPulmonary VentilationPerfusionLungTopics in magnetic resonance imaging : TMRI
researchProduct

Effects of Pressure, Temperature, and Particles Size on O2 Diffusion Dynamics in Silica Nanoparticles

2013

The O2 diffusion process in silica nanoparticles is experimentally studied in samples of average radius of primary particles ranging from 3.5 to 20 nm and specific surface ranging from 50 to 380 (m2/g). The investigation is done in the temperature range from 98 to 177 °C at O2 pressure ranging from 0.2 to 66 bar by measuring the interstitial O2 concentration by Raman and photoluminescence techniques. The kinetics of diffusion can be described by the Fick’s equation with an effective diffusion coefficient depending on the temperature, O2 pressure, and particles size. In particular, the dependence of the diffusion coefficient on the pressure and nanoparticles size is more pronounced at lower …

Materials scienceDiffusionAnalytical chemistryNanoparticleAtmospheric temperature rangeSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialssymbols.namesakeGeneral EnergyDiffusion processsymbolsGrain boundary diffusion coefficientEffective diffusion coefficientPhysical and Theoretical ChemistryRaman spectroscopyBar (unit)The Journal of Physical Chemistry C
researchProduct